EXPERIMENTAL STUDY OF SHEAR BEHAVIOR OF REINFORCED CONCRETE BEAM-COLUMN JOINTS
DOI:
10.5281/zenodo.20025633Published:
2026-01-31Downloads
Abstract
Beam-column joints must be designed to be sufficiently strong and capable of withstanding shear forces (horizontal) and factored vertical forces resulting from theiformation of plastic hinges at the beam ends when seismic forces act. The use of stirrups as reinforcement between columns and beams aims to ensure effective force transfer and prevent cracking or structural damage. However, in practice, several challenges are often encountered that may hinder the implementation process. This study employs an experimental method, where direct testing of specimens is conducted to analyze their behavior. The experimental results, including cracking, load, and Deformation, are analyzed to obtain values for strength, ductility, energyidissipation, and joint capacity. Based on the test results, specimen BJ-2 demonstrated a 51.30% increase in capacity compared to specimen BJ-1. However, in terms of ductility, BJ-1 had a higher average value of 3.59, while BJ-2 had a value of 2.8. Regarding energy dissipation, BJ-1 had a lower value of 0.12831 compared to BJ-2, which reached 0.15069. Both specimens experienced initial cracking, first yielding, and ultimate conditions. Additionally, the joint capacity of specimen BJ-2 was 1.7 times greater than that of specimen BJ-1.
Keywords:
Beam-Column Joint Without Stirrups Deformation First Crack Ultimate Dissipation Energy Joint Shear Capacity.References
Purwanto, Edy, 2013, Kinerja Join balok kolom Beton Bertulang Dengan Pembebanan Statik, Jurnal Matrik Teknik Sipil, Universitas Negeri Surakarta.
Ristanto E, Laksmi I dan Suryadi. 2015. Analisis Join Balok Kolom dengan Metode SNI 2847-2013 dan ACI 352R-2002 pada Hotel Serela Lampung, JRSDD, Vol. 3, No. 3, Hal:521 – 540 (ISSN:2303-0011)
Setiawa A. 2012. Analisis Join balok kolom Beton Bertulang Proyek Pembangunan Gedung Dprd-Balai Kota Dki Jakarta. ComTech Vol.3 No. 1: 711-717
Wang et. al, Chu Kia, 1993, Reinforcment Concreate Design Fourth Edition, PT Glora Aksara Pratama, Jakarta
American Concrete Institute. 2005. “Acceptance Criteria for Moment Frames Based on Structural Testing and Commentary”, ACI 374.1, American Concrete Institute
Badan Standardisasi Nasional. 2019. SNI 1726-2019. Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung Dan Non Gedung, 8, 254.
Badan Standardisasi Nasional. 2019. Persyaratan Beton Struktural untuk Bangunan Gedung dan Penjelasan (SNI 2847:2019). Badan Standardisasi Nasional, 8, 695.
License
Copyright (c) 2026 Ihsanul Ama, Rendy Thamrin, Ruddy Kurniawan

This work is licensed under a Creative Commons Attribution 4.0 International License.